Vietnam: Permissible levels of high frequency electromagnetic intensity in the workplace

On June 30, 2016, the Ministry of Health (Hanoi, Vietnam) issued Circular 21/2016/TT-BYT stipulating the National Technical Regulation - High Frequency Electromagnetic - Permissible Exposure Level of High Frequency Electromagnetic Intensity in the Workplace

According to the provisions of Circular 21/2016/TT-BYT, the permissible levels of high frequency electromagnetic intensity in the workplace do not exceed the values specified in the table below:

High-Frequency Electromagnetic Field (1)
Frequency Electric Field Intensity (E) (V/m) Magnetic Field Intensity (H) (A/m) Power Density (P) (W/cm2) Average Measurement Time (minutes)
3KHz-65KHz 614 24.6 (2) 6
>65KHz-1MHz 614 1.6/f(3) - (2) 6
>1MHz-10MHz 614/f(3) 1.6/f(3) - (2) 6
>10MHz-400MHz 61 0.16 10 6
>400MHz-300GHz 61 0.16 10 6

Notes:

(1) The values of electric field intensity and magnetic field intensity at the workplace may be obtained from average spatial sampling values over an area with nominal dimensions of 30cm x 30cm.

(2) In these frequency ranges, measuring power density in this unit is inappropriate.

(3) f is the frequency in MHz.

More details can be found in Circular 21/2016/TT-BYT which takes effect in Vietnam from December 01, 2016.