Multi-path Error Limits of GSM 900 at RX Noise Levels in Vietnam

On December 08, 2016, the Ministry of Information and Communications issued Circular 30/2016/TT-BTTTT stipulating the National Technical Regulations on GSM mobile communication base station equipment.

According to the provisions of Circular 30/2016/TT-BTTTT, the cross-path error limits of GSM 900 at the RX noise level include:

Channel Type Error Measurement Parameter Error Rate under Specified Transmission Conditions
TU50 (no SFH) TI5 (no SFH)  
FACCH/F (FER) 9.5 % 9.5 %
E-TCH/F43.2 NT (BLER) 10 % 10 %
E-TCH/F32.0 T (BER) 0.1 % 0.1 %
E-TCH/F28.8 T (BER) 0.1 % 0.1 %
E-TCH/F28.8 NT (BLER) 10 % 10 %
TCH/FS (FER) 6.0α % 6.0α %
- class lb (RBER) 0.40/α % 0.40/α %
- class II (RBER) 8.0 % 8.0 %
PDTCH/MCS-5 to 6 (BLER) 10 % 10 %
PDTCH/MCS-7 (BLER) 10 % 10 %
PDTCH/MCS-8 (BLER) 30 % 30 %
PDTCH/MCS-9 (BLER) 30 % 30 %
PDTCH/UAS-7 to 9 (BLER) 10 % 10 %
PDTCH/UAS-10 (BLER) 10 % 10 %
PDTCH/UAS-11 (BLER) 10 % 10 %
PDTCH/UBS-5 to 10 (BLER) 10 % 10 %
PDTCH/UBS-11 (BLER) 10 % 10 %
PDTCH/UBS-12 (BLER) 10 % 10 %

See related provisions at Circular 30/2016/TT-BTTTT effective from May 1, 2017.